Troubleshooting guide – PRG AutoPar User Manual 2.1 User Manual

Page 37

Advertising
background image

AUTOPAR

®

WASH LUMINAIRE USER MANUAL

29

Troubleshooting Guide

The following table provides a list of common failures and possible solutions.

Symptom

Message

Solution(s)

Refer to...

No power to luminaire.

n/a

Ensure power cable is properly connected to Neutrik
input connector.

Ensure power is switched on at source (mains,
disconnect box, etc.)

page 13

No DMX512 control.

No Comm

Ensure data cable is connected to DMX In connector.

Ensure DMX512 address setting is correct.

page 13

page 15

DMX512 control not working
correctly throughout daisy chain.

n/a

Ensure data cables are correctly configured.

Ensure termination connector is installed at last
luminaire in data link.

page 13

page 13

Erratic control of luminaire(s).

n/a

Ensure termination connector is installed at last
luminaire in data link.

Ensure termination connector is properly configured.

page 13

page 10

Lamp does not strike at power-up.

n/a

Configure lamp to start at power-up.

page 19

Timing Channels not working.

n/a

Ensure Timing Channels are enabled.

page 20

Pan mechanism not operating
correctly.

n/a

Ensure yoke leg covers are installed. (Light beams from
adjacent fixtures can affect the optical pan encoder,
causing it to lose track.)

n/a