Eddy User's Guide

70

AT+UARTCONFIG,Baudrate,Parity,Stopbit,Hwfc

Response OK

Purpose

Set Serial parameters

Parameter
s

Baudrate=1200/2400/4800/9600/14400/19200/38400/57600/115200/230400/460800/9
21600 (Default=9600)
Parity=N/E/O (Default=N)
Stopbit=1/2 (Default=1)
Hwfc(Hardware Flow Control)=0/1 (Default=1)

Descriptio
n

The Serial parameters can be set or changed. The factory default is 9600, N, 1, 1.
To take effect the ATZ command must be used or Powercycle the unit.

Example

AT+UARTCONFIF,115200,N,1,1

AT+BTINFO?

Response

112233445566,DeviceName,Mode,Status,Auth,Encryp,FlowControl
OK

Purpose

Display Bluetooth settings

Description The current Bluetooth settings are displayed including BD address, Device name,

Operation mode, Operation status, Authentication, Data Encryption, and Hardware Flow
Control. The initial value of Device name is ‘ESD100V2_v2.0.0-445566’. ESD stands
for Eddy-BT, v2.0.0 for the version of firmware, and 445566 for the last 6 digits of BD
address.
Mode=MODE0/MODE1/MODE2/MODE3
Status=STANDBY/PENDING/CONNECT
Auth=0/1 (Authentication is not activated when 0)
Encrypt=0/1 (Encryption is not activated when 0)
FlowControl=HWFC/NoFC

AT+BTINQ?

Response

112233445566,FriendlyName,CoD
112233445566,FriendlyName,CoD
112233445566,FriendlyName,CoD
OK

Purpose

Search Bluetooth devices nearby

Description The Bluetooth devices in Inquiry scan mode nearby are displayed with their BD

addresses, Device names, and Class of device.
Maximum 15 devices are scanned for 30 seconds. (Default 15 value in S-register 24)