Solvline Eddy Serial v2.5.1.1 User Manual
Page 70
Eddy User's Guide
70
AT+UARTCONFIG,Baudrate,Parity,Stopbit,Hwfc
Response OK
Purpose
Set Serial parameters
Parameter
s
Baudrate=1200/2400/4800/9600/14400/19200/38400/57600/115200/230400/460800/9
21600 (Default=9600)
Parity=N/E/O (Default=N)
Stopbit=1/2 (Default=1)
Hwfc(Hardware Flow Control)=0/1 (Default=1)
Descriptio
n
The Serial parameters can be set or changed. The factory default is 9600, N, 1, 1.
To take effect the ATZ command must be used or Powercycle the unit.
Example
AT+UARTCONFIF,115200,N,1,1
AT+BTINFO?
Response
112233445566,DeviceName,Mode,Status,Auth,Encryp,FlowControl
OK
Purpose
Display Bluetooth settings
Description The current Bluetooth settings are displayed including BD address, Device name,
Operation mode, Operation status, Authentication, Data Encryption, and Hardware Flow
Control. The initial value of Device name is ‘ESD100V2_v2.0.0-445566’. ESD stands
for Eddy-BT, v2.0.0 for the version of firmware, and 445566 for the last 6 digits of BD
address.
Mode=MODE0/MODE1/MODE2/MODE3
Status=STANDBY/PENDING/CONNECT
Auth=0/1 (Authentication is not activated when 0)
Encrypt=0/1 (Encryption is not activated when 0)
FlowControl=HWFC/NoFC
AT+BTINQ?
Response
112233445566,FriendlyName,CoD
112233445566,FriendlyName,CoD
112233445566,FriendlyName,CoD
OK
Purpose
Search Bluetooth devices nearby
Description The Bluetooth devices in Inquiry scan mode nearby are displayed with their BD
addresses, Device names, and Class of device.
Maximum 15 devices are scanned for 30 seconds. (Default 15 value in S-register 24)