Solvline Eddy Serial v2.5.1.1 User Manual

Page 72

Advertising
background image

Eddy User's Guide

72

TASK3   DISCONNECT
TASK4   000195000004

AT+BTMODE,n

Response

OK

Purpose

Set operation mode

Parameters n=0: MODE0 (Default)

n=1: MODE1
n=2: MODE2
n=3: MODE3

Description When the operation status is ‘Pending’ currently, change the status to ‘Standby’

with AT+BTCANCEL prior to this command.
To take effect the ATZ must be executed or Powercycle the unit

Example

AT+BTMODE,2
OK
ATZ

AT+MULTI,n

Response

OK

Purpose

Set multiple connection mode

Parameters n=0: Single Connection Mode (Default)

n=1: Multi-Drop Mode
n=2: Node Switching Mode

Description Set single connection mode, multi-drop mode or node switching mode.

+++

Response

OK

Purpose

Convert the operation status of ‘Connect’ to ‘Standby’

Description In ‘Connect’ status, data from host is transmitted to the other side Bluetooth device,

and any AT command is not accepted but this command, which is not echoed on the
screen.
When Eddy-BT encounters a character ‘+’ from host, it stops the data transmission
and waits for next 2 characters. If the next 2 characters aren’t both ‘+’, it restart to
transmit data including the first ‘+’ as well. If not, it converts the operation status to
‘Standby’.
If the data from host includes ‘+++’, it will convert the operation status to
‘Standby’. Notice that Eddy-BT holds data transmission when it encounters ‘+’,
until receiving next character.
‘+’ is an escape sequence character by default, which is changeable by
AT+SETESC.

Advertising