Solvline Eddy Serial v2.5.1.1 User Manual

Page 83

Advertising
background image

Eddy User's Guide

83

of 0. In case of 3E0100, bluetooth devices with COD 3E0100 are inquired.

S45: Inquiry Access Code (default 0x9E8B33)

Inquiry access code is used during inquiry state. The reserved IAC addresses are 0x9E8B00 ~ 0x9E8B3F. The

general inquiry IAC is 0x9E8B33.

Eddy-BT is able to find the Bluetooth devices that are configured as the same IAC.

S46: BD Address of Last Connected Device

This saves the BD address of the Bluetooth device connected most recently in single connection mode. This saves

the Task1 BD address of the Bluetooth device connected most recently in a multiple connection mode.

S48: Low Power Max Interval (default 5000)

This is the max interval value to use low power mode, which is set to 5000 initially. (5000 x
625μsec = 3125msec)

S49: Low Power Min Interval (default 4500)

This is the min interval value to use low power mode, which is set to 4500 initially. (4500 x
625μsec = 2812msec)

A small interval increases power consumption, a large interval increases latency.

S52: Low Power Timeout (default 5)

This is the low power timeout value, which is set to 5 initially. (5sec)

During no data transmission in the timeout, Eddy-BT will be in low power mode to save the power.
Therefore, it takes a few seconds to wake the Eddy-BT out of low power mode.

S54: BD Address of Last Connected Device

This saves the Task2 BD address of the Bluetooth device connected most recently in a multiple connection mode.

S55: BD Address of Last Connected Device

This saves the Task3 BD address of the Bluetooth device connected most recently in a multiple connection mode.

S56: BD Address of Last Connected Device

This saves the Task4 BD address of the Bluetooth device connected most recently in a multiple connection mode.

S57: Slave Disconnect Timeout (default 3)

This S57 register value defines the time period in seconds that a master unit waits in case a slave unit does not

receive the data sent from the master. For this time period, the master unit will not send data to all slave units if any

slave unit does not receive the data. If the slave unit does not receive the data after this time period elapses, the

master unit will disconnect the connection with the problematic slave unit. The value should be greater than 0 and

smaller than the Supervision Timeout(S37).