AT+BTFP,n

Response

OK

Purpose

Set generation of link key every time of connection

Parameters n=0: Inactivate (Default)

n=1: Activate

Description If n is set to 1, Eddy-BT asks for the pin code every time a connection is made. This can

be used to increase security.

AT+BTSEC,Authentication,Encryption

Response

OK

Purpose

Set authentication and data encryption

Parameters

Authentication=0: Inactivate (Default)
Authentication=1: Activate
Encryption=0: Inactivate (Default)
Encryption=1: Activate

Description If the authentication is activated, the pin code must be set by AT+BTKEY command.

Data encryption cannot be used when authentication is not enabled, i.e.
Authentication=0 and Encryption=1 will not work properly.

AT+BTNAME=$

string

Response

OK

Purpose

Change device name

Parameters

$string= New device name (Default=”ESDV2_v2.0.0-445566”)

Description Eddy-BT can have a user friendly name for easy identification. The name allows up to 30

alpha-numeric characters.

Example

AT+BTNAME=”My-Eddy-BT”

AT+BTLPM,n

Response

OK

Purpose

Set low power mode

Parameters n=0: Inactivate (Default)

n=1: Activate

Description During no data transmission, Eddy-BT can be in low power mode to save the power. It

takes a few seconds to wake the Eddy-BT out of low power mode.