[Rear]

10. Functional earth terminal [SIGNAl GND]

Hum noise may be generated when external

equipment is connected to the unit. Connecting

this terminal to the functional earth terminal of the

external equipment may reduce the hum noise.

Note: This terminal is not for protective earth.

11. Fuse holders

Requires an AC fuse.

Ratings: 250 V, T6.3A L

12. DC output terminals

[POwER OUT 19-33V mAX 5A]

DC 33 V max., 5 A max.

Supply DC power to the SX-2000SM or VX-2000

or other DC-operated devices except power

amplifiers.

13. DC output terminal

[POwER OUT 19-33V mAX 25A]

DC 33 V max., 25 A max.

Supplies DC power to power amplifiers or other

DC-operated devices.

14. Fuses

Provided in each DC output.

Type and rating: Blade-Type Fuse 35 A

Remove the protection cover when replacing the fuse.

15. Battery connection terminal

[BATTERy POwER IN]

Connects to the backup sealed lead-acid battery.

Recommended battery:

2 x Panasonic LC-X1265PG/APG

2 x Panasonic LC-XA12100P

2 x Panasonic LC-XB12100P*

2 x Yuasa NP65-12

2 x Yuasa NPL100-12

* Compliant with EN54-4

16. Control connectors [DS lINk IN, OUT]

• DS LINK IN connector

Connects to DS LINK connector of the VX-2000

system, SX-2000 system, or VM-3000 system.

• DS LINK OUT connector


Connects to DS LINK IN connector of a daisy-

chained unit.


Note: This connection is required only when 2

to 4 units are connected to one DS LINK

connector.

17. Fuse holders

The specified AC fuses are incorporated.

Ratings: 250 V, T8A H

18. AC inlets (AC POwER IN1, IN2)

Connect to power source of 220 - 230 V AC, 50/60

Hz using the supplied power cords.

Connect both AC POWER IN 1 and AC POWER

IN 2 to AC mains power outlet from single circuit

breaker line.
Allowable power capacity is 1800 W each, 3600 W in

total. Power applied to both inlets is sent to individual

DC power supply circuits, then finally joined together,

operating entire circuit inside the unit.

19. DC output terminal

[POwER OUT 24V(16-25V) mAX 0.3A]

DC 24 V max., 0.3 A max.

Supplies DC power to the DC-operated devices

except power amplifiers.

20. Temperature sensor connection terminal

[TEmPERATURE SENSOR]

Detects the ambient temperature of the backup

battery, and performs temperature compensation

for the charging voltage. For the installation

instructions, refer to p. 11.

The temperature sensor has a serial number label

attached to it.

When connecting the temperature sensor to this

terminal, confirm the serial number matches that

of the VX-3000DS.

10

16

Protection cover

12

17

15

13

11

18

TEMPERA

TURE

SENSOR

24V(16-25V)

POWER OUT

MAX 0.3A

IN

OUT

DS LINK

View with the cover removed

14

20

19

20

Advertising