Caution – Toa VX-3000DS CE-GB User Manual

Page 9

Advertising
background image

9

• Strip the cable end long enough (30 mm ± 5 mm) to be

fully clamped. Otherwise, its outer jacket prevents the

cable conductor from being tightly secured, causing poor

contact.

[Connecting the battery]

Note correct polarity (positive and negative orientation) when connecting

the power supply cord. Reversed polarity connections will cause damage

to the system.

• Insert the battery cable into the correct position in the battery terminal referring to the terminal's cross sectional

diagrams below.

18 kΩ (1/4 W)

Battery

Battery

Notes

To avoid battery failure and charger failure, take care of the following points.

• If batteries not recommended by the manufacturer are used and a charger failure occurs, connect a resistor

of 18 kΩ (1/4 W) parallel to the batteries.

• Use the specified type of batteries and capacity.

• When batteries are connected together in a series-parallel arrangement, the inter-connecting cables must be

of equal length and resistance to insure equalization of the load.

• Do not mix batteries with different capacity, new and old batteries, or batteries of different manufacturers.

Doing so may cause different characteristic values among batteries, possibly resulting in damage to the

batteries themselves or the connected equipment.

CAUTION

Correct position of the cable insertion

Incorrect position of the cable insertion

Wrong insertion position of the cable or a forked

cable insertion causes poor contact or insufficient

connection tightness, making the cable come off to

possibly cause short-circuit accident.

Correct

Incorrect

Cable conductor

Cable clamp