Factory setting parameters, External modulating control – TriangleTube 399 Solo User Manual

Page 61

Advertising
background image

55

External Modulating Control

Factory Setting Parameters

1

140ºF

DHW Setting

2

01

DHW Application Selection

3

01

CH Application Selection

4

186ºF

CH Maximum Boiler Operating Setpoint

10

86ºF

CH Minimum Boiler Operating Setpoint

11

00ºF

CH Reset Curve Coldest Day

12

64ºF

CH Reset Curve Warmest Day

13

-22ºF

Frost Protection Setpoint

18

32ºF

CH Block Temperature Setting

19

00 Minutes

Boost Feature Setting

20

00ºF

Parallel Shift Value

21

46ºF

Setpoint Value Addition for DHW

32

01 Minutes

CH Circulator Post Pump Time Period

33

03 x 10.2 Sec.

DHW Circulator Post Pump Time Period

38

02ºF

DHW On Differential

39

06ºF

DHW Off Differential

40

03 x 10.2 Sec.

CH Call Blocking Time

41

00 x 10.2 Sec.

DHW Call Blocking Time

42

00 x 10.2 Sec.

DHW to CH Call Blocking Time

43

00 Minutes

DHW Priority Timeout

45

00

CH Operating Signal Selection

46

02

DHW Operating Signal Selection