VACUUBRAND MZ 2C VARIO User Manual

Page 29

Advertising
background image

page 29 of 51

Documents are only to be used and distributed completely and unchanged. It is strictly the users´ responsibility to check
carefully the validity of this document with respect to his product. manual-no.: 999034 / 22/04/2008

Setting the pumping speed

45.0

MODE

➨ Press key MODE.

☞ Switching to vacuum control is only possible, if pumping

down is activated (after pressing key START).

☞ The actual pressure is stored as new set point, e. i. the con-

troller keeps the pressure constant.

☞ Press key MODE again to activate automatic mode.

Changing to mode vacuum control

Setting of speed:
Setting the value for the speed by using key Mode

▲ or ▼:

☞ To activate set mode: Press key shortly. The current speed

is displayed for one second.

☞ With a second tip within one second or continuous pressing:

☞ Set speed. The new set point is stored when the key is re-

leased.

☞ The maximum speed restricts the evaporation rate in case

of low boiling solvents and a carry over of substances.

☞ Setting the motor speed ”HI” (above 60 Hz) enables fast-

est pumping down to the best ultimate vacuum.