Important notes regarding the use of gas ballast – VACUUBRAND PC 3012 VARIO plastic housing User Manual

Page 45

Advertising
background image

page 45 of 129

its. Clean the pump if necessary to avoid an increase of

the pump’s operating temperature.

Operation with silencer (optional) at the outlet: Operating

the pump at a high inlet pressure or pumping dusty gases

for a long time may cause clogging of the silencer. Check

the silencer regularly and replace if necessary.

In case of overload, the motor is shut down by a

self-hold

thermal circuit breaker in the winding.

Note: Only a manual reset is possible.

Press the START/

STOP key at the controller to confirm the error message.

Switch off the pump and disconnect the electrical power

cord. Identify and eliminate the cause of failure. Wait ap-

prox. five minutes before restarting the pump.

Check fan regularly for dust/dirt. Clean if necessary. Avoid

overheating (e.g., due to hot process gases).

A warm up period (approximately 15 min.) is required to

ensure that the rated ultimate vacuum and pumping speed

are attained. Avoid overheating (e.g., due to hot process

gases).

Important notes regarding the use of gas bal-

last

Gas ballast is a continuous purge to keep the pump’s in-

terior as clean as possible and to reduce the possibility of

condensation inside the pump.

Air and pumped media might react inside the pump or

at the outlet of the pump and form hazardous or explo-

sive mixtures, when you use air rather than inert gas

for the gas ballast. This constitutes a risk of significant

damage to equipment and/or facilities, a risk of per-

sonal injury or even loss of life.

+

Make sure that air/gas intake through the gas ballast

valve can never lead to hazardous, explosive or other-

Advertising