Fault

Possible cause

Remedy

❑ Pump does not

achieve its ultimate

vacuum or usual

pumping speed.

➨ Pressure below ”Mini-

mum” in Auto mode?

✔ Change switch off pres-

sure (”Minimum”) if neces-

sary.

➨ Pump too hot?

✔ Allow pump to cool down.

Determine and eliminate

the cause of overheating.

❑ Pump too noisy.

➨ Atmospheric or high

pressure at the pump

inlet?

✔ Connect hose or silencer

to pump outlet. Be careful

not to cause outlet over-

pressure, especially with

condensable vapors.

➨ Diaphragm crack or

diaphragm clamping

disc loose?

✔ Perform maintenance.

➨ Other than above men-

tioned causes?

✔ Contact local distributor.

❑ Pump seized.

✔ Contact local distributor.

A service manual with exploded view drawings, spare parts list and

directions for repair is available on request.

+

The service manual is intended for trained service people only.

* only if ”Sound” ”On” is selected