Cleaning and inspecting the pump heads, Md 4 nt vario / mv 2 nt vario) – VACUUBRAND MV 2 NT VARIO User Manual

Page 86

Advertising
background image

page 86 of 106

Tools required (metric):
- 5 mm wide Allen key

- Diaphragm key width 66 mm

Service kit for MD 4 NT VARIO / MV 2 NT VARIO ......................................696861

Service kit for MV 10 VARIO-B ....................................................................696827

Diaphragm key (width 66 mm) ...................................................................636554

Ensure that maintenance is done only by suitably

trained and supervised technicians.

The valves and diaphragms are wear parts. If the rated

ultimate vacuum is no longer achieved or in case of in-

creased noise level, the pump interior, the diaphragms

and the valves must be cleaned and the diaphragms and

valves must be checked for cracks or other damage.

All bearings are encapsulated and are filled with long-life

lubricant. Under normal operating conditions, the drive

system is maintenance free.

In demanding circumstances, it may be efficient to check

and clean the pump heads on a regular basis. In normal

use, the lifetime of the diaphragms and valves is typically

15,000 operating hours.

- Prevent internal condensation, transfer of liquids or

dust. The diaphragms and valves will be damaged if

liquid is pumped in significant amount.

- Carry out maintenance frequently if the pump is ex-

posed to corrosive media or in case of deposits.

- Regular maintenance will improve the lifetime of the

pump and also protect both users and the environment.

NOTICE

Cleaning and inspecting the pump heads

(MD 4 NT VARIO / MV 2 NT VARIO)

Advertising
This manual is related to the following products: