OIL BURNER COMPONENTS IDENTIFICATION

RIELLO 40 SERIES

F10 BURNER COMPONENTS

1. Lockout indicator lamp and

9.

End cone

Reset button

10. Turbulator adjustment screw

2. Primary control

11. Air tube cover

3. Primary control sub-base

12. Coil

4. Pump pressure regulator

13. Vacuum gauge connection port

adjustment screw

14. Pressure gauge and bleeder port

5. Motor

15. Return fuel line port

6. Capacitor

16. Supply fuel line port

7. Air adjustment fixing screws

17. Adjustable collar

8. Air shutter

18. Mounting flange with gasket

SERIAL NUMBER IDENTIFICATION

The Riello 15 character serial number, example, 97 A 8511111 00025, is identified as
follows: 97 = last two digits of the year of manufacture; A = Bl-week of manufacture;
8511111= burner product code; 00025 = increment of 1 for each burner produced - spe­
cific to product code - reset to zero each January l^t.

INITIAL SET-UP

A)

Remove burner and air tube from cartons. Check parts list (inside cover) to ensure

all parts are present.

B)

Remove burner cover by loosening the three screws securing it. Remove control

box and air tube cover (see page 7).

C)

Remove

drawer

assembly

from

air

tube,

insert

nozzle

and

set

turbulator

adjustment for specific input required (see pages 7 & 8), then set aside.

D)

Mount air tube to burner chassis (see page 3).

F 1 0 - 2