NOZZLE PLACEMENT

A)

Determine the proper firing rate

for the boiler or furnace unit, consid­

ering

the

specific

application,

then

use the Burner Set-up chart on page

12 to select the proper nozzle and

pump pressure to obtain the required
input from the burner.

B)

Remove the NOZZLE ADAPTER

(2) from the DRAWER ASSEMBLY by

loosening the SCREW (1).

C) Insert the proper NOZZLE into the

NOZZLE ADAPTER and tighten securely (Do not overtighten).

D)

Replace adapter, with nozzle installed, into drawer assembly and secure with

screw (1).

INSERTION/REMOVAL OF DRAWER ASSEMBLY

A)

To remove drawer assembly, loosen SCREW (3), then unplug CONTROL BOX (1)

by carefully pulling it back and then up.

B)

Remove the AIR TUBE COVER PLATE (5) by loosening the two retaining

SCREWS (4).

C)

Loosen

SCREW

(2),

then

slide the complete

drawer assembly out of the

combustion head as shown.

D)

To insert drawer assembly, reverse the procedure in items A to C above, then

attach fuel line to the pump.

F 1 0 - 7