METHOD 2 - SEMI-FLANGE COLLAR

A) Follow item C from METHOD 1.

B)

Align the air tube and attached adjustable collar so air tube is centered in the

burner access hole of the boiler/furnace unit. Mark the center of the two holes in the

ADJUSTABLE COLLAR on to the front plate of the heating unit. Then drill 1/4 inch

(6.5 mm) holes through the front plate of the unit, using marks as a guide.

C)

Install two short BOLTS (1) through the front plate of the heating unit from the

inside, and secure on the outside using the two special CHROME NUTS (2).

D) Follow item D from METHOD 1.

METHOD 3 - PEDESTAL MOUNT

Secure

the

MOUNTING

FLANGE

to

MOUNTING

PEDESTAL

using

the

hardware

provided with the pedestal. Secure burner to MOUNTING FLANGE as in METHOD 1,
items A, C and D.

NOTE; It is suggested that the pedestal be anchored in position on the floor by
installing brackets over the pedestal tube and securing brackets to the floor.

WARNING: WHEN THE COMBUSTION CHAMBER IS LINED WITH A REFRACTORY

MATERIAL, IT IS IMPERATIVE THAT THE END CONE NOT PROTRUDE INTO THE

CHAMBER AREA, AS EXCESSIVE HEAT AT BURNER SHUT-DOWN WILL DAMAGE
THE END CONE.

ELECTRICAL CONNECTIONS

It is advisable to leave the control box off the sub-base while completing the electrical

connections to the burner.

1) Wire access hole

(Use BX electrical connector)

Earth ground conductor terminal
(GREEN WIRE)

Hot conductor terminal
(BLACK WIRE)

Neutral conductor terminal
(WHITE WIRE)

Strain relief clamp

WARNING: The hot (black) wire

must be connected to the L ter­
minal

and

the

neutral

(white)

wire must be connected to the

N

terminal or the primary safety
control will be damaged.

Do not connect either wire to the

2

)

3

)

4

)

5)

^Terminal.

F I O - 5