Application field wiring, Factory, Wired – Sears Riello F10 User Manual

Page 8: Sub-base, Factory wired sub-base

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

The burner may be controlied using either a DIRECT LINE VOLTAGE control circuit

(120V AC 60 cycle)

OR a LOW VOLTAGE control (24V AC 60 cycle) using a R8038A

Honeywell switching relay or equivalent.

Using the appropriate diagram below, make electrical connections to burner. All wiring

must be done in accordance with existing electrical codes, both national and local.

When all electrical connections have been made, the control box may be put back in

place on the sub-base.

WARNING: DO NOT activate burner until proper oil line connections have been

made, or failure of the pump shaft seal may occur.

APPLICATION FIELD WIRING

DIRECT LINE VOLTAGE

120 V

LOW VOLTAGE

AC

FUSE 15A

^6

/

LINE

SAFETY

g

/

SWITCH

^■6 / OPERATING

/ LIMIT SWITCH

b o / SAFETY

^

J

LIMIT SWITCH

N

FACTORY

WIRED

SUB-BASE

D5995

REMOTE SENSING OF SAFETY LOCKOUT: The SAFETY SWITCH in the 530SE

CONTROL BOX is equipped with a contact allowing remote sensing of burner lockout.
The electrical connection is made at terminal 4 (•) on the SUB-BASE. Should lockout
occur the 530SE CONTROL BOX will supply a power source of 120Vac to the con­

nection terminal. The maximum allowable current draw on this terminal (4) is 1 Amp.

WARNING: If a neutral or ground lead is attached to this terminal, the CONTROL

BOX on the burner will be damaged should lockout occur.

F 1 0 - 6