9. After reassembling, turn gas on and check all joints for gas

leaks using a soapy solution. All leaks must be repaired im­
mediately.

I

LP Conversion

An accessory kit shall be used to convert to propane gas use, see
the furnace rating plate for the LP conversion accessory kit part
number.

CAUTION

CARBON MONOXIDE POISONING HAZARD.

Failure to follow this warning can result in

death, property damage and/or personal

injury.

NOx inserts for use with Natural Gas units
ONLY. If LP Gas is required, NOx inserts must
be removed.

WARNING

FIRE, EXPLOSION, UNIT DAMAGE HAZARD.

Failure to follow this warning can result in

death, property damage and/or personal

injury.

An LP conversion accessory kit is required

when operating the furnace with LP gas.

‘SMPLs and NSMPLs contain NOx inserts.

For LP conversion remove screws that secure the NOx insert and

discard insert.

Reinstall screws. See Figure 37

NOTE: It is very important to reinstall the NOx insert mounting

screws.

Main Burner Flame Check

Allow the furnace to run approximately 10 minutes. Then inspect
the main burner flames. See Figure 38.

Check for the following:

• Stable and blue flames. Dust may cause orange tips or

wisps of yellow, but flames MUST NOT have solid, yellow

tips.

• Flames extending directly from burner into heat exchanger.

• Flames do NOT touch sides of heat exchanger

If any problems with main burner flames are noted, it may be nec­

essary to adjust gas pressures or check for drafts.

NOTE: For Ignitor location see Figure 39.