Horizontal

If you purchased a multi-position furnace, it can be installed hori­

zontally in an attic, basement, crawl space, alcove, or suspended
from a ceiling in a basement or utility room in either a right or left
airflow position, (see Figure 4)

Horizontally installed furnaces may be vented out the top of the

unit or out the side facing up. See"Side venting" for instructions to
rotate the vent to the side.

The minimum clearances to combustibles MUST be maintained
between the furnace and adjacent construction, as shown in
Figure 1 and Figure 2. ONLY the corner of the cabinet is allowed
to contact the rafters as shown in Figure 4. All other clearances
MUST be observed as shown in Figure 1 and Figure 2.

If the furnace is to be suspended from the floorjoists in a basement

or crawl space or the rafters in an attic, it is necessary to use steel

pipe straps or an angle iron frame to attach the furnace. These

straps should be attached to the furnace bottom side with sheet
metal screws and to the rafters or joists with bolts. The preferred
method is to use an angle iron frame bolted to the rafters or joists.

If the furnace is to be installed at ground level in a crawl space, con­

sult local codes. A concrete pad T" to 2" thick is recommended.

Twenty four inches (24") is required between the front of the fur­
nace and adjacent construction or other appliances. This should

be maintained for service clearance.

Keep all insulating materials clear from louvered door. Insulating

materials may be combustible.______________________________

The horizontal furnaces may be installed directly on combustible

wood flooring or supports, however, it is recommended for further

fire protection cement board or sheet metal is placed between the
furnace and the combustible wood floor and extend

12 ' beyond

the front of the furnace louver door. (This is a recommendation
only, not a requirement).

This furnace MUST NOT be installed directly on carpeting, tile or
other combustible material other than wood flooring or supports.

Downflow

WARNING

FIRE HAZARD.

Failure to install unit on noncombustibie subbase

could result in death, personal injury and/or property

damage.

Place furnace on noncombustible subbase on
downflow applications, unless installing on
noncombustible flooring.

If you purchased a Multi-position furnace (N

8MP or *8MP) it may

be installed in a downflow configuration, (see Figure 5). The mini­
mum clearances to combustion construction MUST be maintained
between the furnace and adjacent construction, as shown in
Figure 1 and Figure 2.

In addition to clearances in Figure 1 and Figure 2, clearance for

the vent pipe must be considered.

A subbase for combustible floors MUST be used when the furnace
is installed as a downflow on combustible material. See Duct­

work and /T7fer" (Downflow Section). The outlet flange must be

bent flat for downflow installation.

When installing a four-position furnace in the downflow position

(not the *

8DNL furnace), the logo is to be repositioned so that it is

rightside-up as follows:

T8MPN/L

1. Find the door hardware kit that is stored in the furnace and

save it.

2. Carefully remove logo from the outside of burner compartment

door and save it.

3. Carefully remove two small plug buttons from outside of blow­

er compartment door and save them.

4. Remove two thumbscrews from blower compartment door.

5. Install two thumbscrews in holes at other end of blower

compartment door from where thumbscrews were removed.

6. Install new strip of rubber gasket on inside of blower compart­

ment door on edge that does not already have a gasket.

7. Install logo retainer pins into holes in blower compartment door

from which plug buttons were removed.

8. Install plug buttons into holes in burner compartment door from

which logo was removed.

9. Install blower compartment door on furnace with bevel edge

and logo at top.

10. Install burner compartment door on furnace with bevel edge at

bottom.

N8MPN/L, C8MPN/L, H8MPN/L

1. Carefully remove logo from burner compartment door and

save it.

2. Turn the logo rightside-up, and install the logo retainer pins

into holes in burner compartment door.___________________