Circulation Air Blower Data Continued

N8MPN/L125J22 (2){6)

O

im.

3

(A

^

.

£ o

O

o

w

s

c3 "o

c _c

0)

w

X

LU

8MPN150J20 (2){7)

* Denotes Brand

Air Delivery In Cubic Feet per Minute (C.F.M.)

{Furnace Rated @0.5" WC ESP)

TAP

LOW

MED L

MED H

HIGH

.10

1901

2121

2362

2463

.30

1833

2033

2244

2385

.50

1745

1936

2100

2217

.70

1624

1773

1894

2033

.90

1442

1569

1714

1821

1.00

1329

1455

1583

1685

*

3
(/)

£ o

w ®

ui «

_ £

ni y

c c

X

LU

Air Delivery in Cubic Feet per Minute (C.F.M.)

(Furnace Rated @0.5" WC ESP)

TAP

LOW

MED L

MEDH

HIGH

.10

1656

1915

2168

2385

.30

1583

1787

2090

2335

.50

1507

1697

1997

2212

.70

1390

1595

1856

2085

.90

1212

1445

1654

1898

1.00

1125

1337

1561

1777

NOTE: (1) Data based on Bottom Only or One Side return.

(2) Data based on Both Sides or Bottom plus One Side

(3) 075F16 Reduce airflow by 5% if Bottom Only return.

(4) 100F20 Reduce airflow by 10% if Bottom Only return.

(5) 125J20 Reduce airflow by 5% if Bottom Only return.

(6) 125J22 Reduce airflow by 10% if Bottom Only return.

(7) 150J20 Reduce airflow by 10% if Bottom Only return.

MAX CFM's

Filter Size

CFM

14" X 25"

1400

16" X 25"

1600

20" X 25"

2000

24" X 25"

2500

Max CFM based on 600 FPM

Filter required for each return-air inlet. Airflow performance includes 1" washable (600 FPM max) filter media.