BODAYS

Inspect and remove lint accumulation in customer furnished exhaust duct work system and
from dryers internal exhaust ducting.

NOTE: THE ACCUMULATION OF LINT IN THE EXHAUST DUCT

WORK CAN CREATE A POTENTIAL FIRE HAZARD.

NOTE: DO NOT OBSTRUCT THE FLOW OF COMBUSTION and VENTI­

LATION AIR. CHECK CUSTOMER FURNISHED BACK DRAFT

DAMPERS IN THE EXHAUST DUCT WORK. INSPECT and RE­
MOVE ANY LINT ACCUMULATION WHICH CAN CAUSE THE
DAMPER TO BIND or STICK.

NOTE: A back draft damper that is sticking partially closed can result in

slow drying and shutdown of heat circuit safety switches or ther­

mostats

NOTE: When cleaning the dryer cabinet(s), avoid using harsh abrasives.

A product intended for the cleaning of appliances is recommended.

B. ADTUSTMENTS

7

DAYS AFTER INSTALLATION and EVERY 6 MONTHS THEREAFTER

Inspect bolts, nuts, screws, (bearing set screws), non-permanent gas connections (unions,
shut-off valves, orifices, and grounding connections). Motor and drive belts

should be

examined. Cracked or seriously frayed belts

should be

replaced. Tighten loose V-belts when

necessary. Complete operational check of controls and valves. Complete operational check of
ALL safety devices (door switches, lint drawer switch, sail switch, burner and hi-limit
thermostats).

C. LUBRICATION

The motor bearings, idler bearings, and tumbler bearings are permanently lubricated.

NO

LUBRICATION IS NECESSARY.