F. dryer operates but is taking too long to dry, Gas models – American Dryer Corp. AD-385 User Manual

Page 61

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

b. Ignitor sparks, burner lights but goes off right away...

1) Direct Spark Ignition (DSI) ignitor out of adjustment...or has failed.

2) Sail switch is fluttering...

a) Lint screen is dirty.

b) Restriction in exhaust duct work.

c. Ignitor does not spark and Direct Spark Ignition (DSI) module locks out (red LED

indicator light stays on)...

1) Fault in high voltage (HV) wire...break or loose connection.

2) Failed ignitor probe assembly.

3) Failed Direct Spark Ignition (DSI) module.

F. Dryer operates but is taking too long to dry...

1. Exhaust duct work run too long or is undersized...back pressure cannot exceed 0.3 inches water

column (W.C.).

2. Restriction in exhaust...

a. Customer-furnished exhaust back draft damper is sticking partially closed.

b. Restriction in duct work...check duct work from dryer all the way to the outdoors.

3. Insufficient make-up air.

4. ImpellorA)lower/fan (3-Phase [30] Models ONLY) rotating in the wrong direction.

5. Lint screen is dirty or is not being cleaned often enough.

6. Inadequate air flow...

a. Impellor (blower/fan) failure.

7.

Gas Models

a. Low and/or inconsistent gas pressure (Gas Models ONLY)...Natural Gas pressure

must be

between 3.5 inches and 4.0 inches of water column, and Liquid Propane (L.P.) pressure

4) Failed gas valve.