Gas models – American Dryer Corp. AD-385 User Manual

Page 54

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

2)

Failure in drive motor circuit...refer to

Item B, and/or Item C in this

Troubleshooting Section.

b. Failed rotational sensor.

c. Broken wire or connection between sensor and microprocessor controller (computer).

2. Microprocessor controller (computer) program (PL02) is set incorrectly in the active mode

("SEn") where the dryer is not equipped with the

OPTIONAL

rotational sensor...program

should be

set as "nSEn".

N. Microprocessor controller (computer) LED display reads "Hot"...

1. Possible overheating condition...microprocessor controller (computer) has sensed a temperature

which has exceeded 220° F.

"Hot" display

will not

clear until temperature sensed has dropped to 220° F or lower and the

microprocessor controller (computer) is manually reset by pressing the "CLEAR/STOP" key.

O. Heating unit is not operating (no heat)...no voltage at heating unit (i.e., DSI module,)

when dryer is first started and both the heat indicator dot and the "HEAT" output LED

ARE ON...

Gas Models

1. Fault in sail switch circuit...

a. Sail switch is out of adjustment or has failed.

b. Sail switch damper is not closing or is fluttering...

1) Lint screen is dirty.

2) Restriction in exhaust.

3) No exhaust air flow...

a) Failed impellor (blower/fan).

b) Fault in impellor (blower/fan) motor circuit.

2. Failed burner hi-limit switch.

3. Failed lint chamber sensor bracket basket (tumbler) hi-limit switch.