P Coins are accepted but do not register...LED display continues to read "FELL"...

1. Failed coin optic sensor.

2. Loose connection in optic sensor harness.

3. Poor ground connection of optic sensor.

4.

Failed microprocessor controller (computer).

Mechanical Coin Meter

A. Dryer will not start...indicator light is off...

1. Dryer control circuit fuse is blown.

2. Open circuit at location...service main fuse or circuit breaker.

3. Failed push to start relay.

4. Failed door switch and/or circuit.

5. Failed coin mechanism.

B. Drive motor not operating (does not start)... Indicator light is on ...

1. Failed drive motor contactor (relay).

2. Failed drive motor.

C.

Drive motor operates okay for a few minutes, and then stops and will not restart..

1. Motor is overheating and tripping out on overload protector...

a. Motor air vents clogged with lint.

b. Low voltage to the motor.

c. Failed motor.

d. Basket (tumbler) is binding...check for obstruction.

e. Failed idler bearings or tumbler bearings.

f. Failed impellor/fan ... out of balance.

42