e. Open main door. The dryer

must stop

and ALL indicator lights on the back side of the microprocessor

(computer) board

must go out.

f. Try to restart the dryer with the main door open.

g. The microprocessor (computer) board's LED display

must read

"DOOR."

h. Close the main door and restart the dryer.

i. Functional check of microprocessor (computer) board is complete.

2. Direct Spark Ignition (DSI) System

a. Upon completing installation of the replacement Direct

Spark Ignition (DSI) module, reestablish power to the
dryer.

b. Start the drying cycle.

c. The ignition (DSI) module's LED indicator will light

"red" for up to approximately 1.5 seconds (pre-purge

time).

d. The module's indicator light will then turn "green."

The gas valve will be energized and the ignitor

probe will spark for approximately 8 seconds. The
burner flame should now be established.

e. With the burner flame on, remove the flame sensor

wire from the FP terminal of the DSI module.

f. The burner flame

must shut off

and the ignition module

must lock out

with the DSI module's indicator light

"red."

/

o

inaccicr

o

|B«d • £»tcpt-»r»o'

ny>tior Stcuor«!

X

J' RM - yt'on

— STA-LS --

t

fM roco^ar 1« 'Cn* rcn-.xc^y

cawr ‘V

33 stcarcs

3T0 -rw

30»*' • 'M

-«■cctor sui .-««ora On'

:s.*.’'nuousiy •etaoce tcnva

Direct Spark

Ignition Control

PCfi USE wifK Ai. GASES

2i VAC 53/6Cfr • A(T3

::smoc>s ' Airg C»‘v<x.5vS

Prstk/ge »5 Seccra» «

3

*

Tfoi -or -carón

i

Sécenos 'ten

u3C«ou' *0 Secanos i'3n

WARNING I

Discorrec! Pcwer 3e'C'e Se-vemg,

NOT FIELD REPAIRABLE.

5x3i=sicn one

I—. Ssr ous -ifv -^av Pesi-i' ,—i

o

0 N

in.

i' ^ 1

1

;

| :

q

I ^

..i . ‘

1

J '

L_

J

g. Stop the drying cycle, with the flame sensor wire still removed, restart the drying cycle.

h. The ignition module

must proceed

through the pre-purge, with the indicator light "red," the ignition trial

time of approximately 8 seconds, with the indicator light "green," and then proceed to lock out with the
indicator light "red."

i. Functional check of the Direct Spark Ignition (DSI) Module is complete.

1) Replace the flame sensor wire from the FP terminal to the DSI module.