A.2.3 back-to-back testing – Dolby Laboratories DP503 User Manual

Page 69

Advertising
background image

A-5

A.2.3

Back-to-Back Testing

For purposes of testing the Model DP503 and Model DP524 in a back-to-back
configuration, a special cable must be constructed. Note that a DTE to DTE
connection is not supported by the RS-449 specification; a standard 37-wire cable
cannot be used to connect the units together. The special cable connects the TT
outputs of the DP503 directly to the ST inputs of the DP503, and to the RT inputs
of the DP524. This cable also connects the SD outputs of the DP503 to the RD
inputs of the DP524, and connects the signal grounds (SG) of the two units. One
end of the cable should be labeled as Encoder (DP503), and the other as Decoder
(DP524.

From

Pin

Connection

To

Pin

Connection

DP503

4

SD+

DP524

6

RD+

DP503

22

SD-

DP524

24

RD-

DP503

5*

ST+

DP524

8

RT+

DP503

17*

TT+

DP524

8

RT+

DP503

23**

ST-

DP524

26

RT-

DP503

35**

TT-

DP524

26

RT-

DP524

19

SG

DP524

19

SG

DP524

1

shield

DP524

n/c

*For convenience, tie pins 5 & 17 together in the connector shell at the
encoder. Run one line to decoder pin 8.

**For convenience, tie pins 23 & 35 together in the connector shell at the
encoder. Run one line to decoder pin 26.

A.2.4

Dolby Fax Cable Pinout, Part No. 83293

A Dolby Fax installation requires the use of a supplied “Y” cable, two of whose
ends are terminated in 37-pin female connectors and which are labeled “encoder”
and “decoder;” and a third end terminated in a 44-pin male connector. Pinouts and
wire colors are as follows:

From

Pin

To

Pin

Connection

Color

DP503

4

VSX

29

SD+

brn

DP503

22

VSX

30

SD-

wht

DP503

5

VSX

42

ST+

red

DP503

23

VSX

41

ST-

grn

DP503

19

VSX

1

shield

blk

DP524

6

VSX

40

RD+

brn

DP524

24

VSX

39

RD-

wht

DP524

8

VSX

37

RT+

red

DP524

26

VSX

38

RT-

grn

DP524

19

VSX

1

shield

blk

VSX

20

VSX

28

RX/Sel

gra

MAIN