Figure 4-4: post trigger with retrigger – ADLINK DAQe-2502 User Manual

Page 38

Advertising
background image

28

Operation Theory

Post-Trigger or Delay-trigger Acquisition with Retrigger

Use post-trigger or delay-trigger acquisition with retrigger when
you want to perform repeated scans with respect to the
repeated triggers. Figure 4-4 illustrates this mode. Two scans
are performed after the first trigger signal, and then waits for
the next trigger signal. When the trigger signal occurs, it per-
forms two more scans.

When retrigger function is disabled, only one trigger signal is
be accepted after retrigger.

NOTE

Retrigger signals asserted during scan process will be ig-

nored.

Figure 4-4: Post Trigger with Retrigger