ADLINK DAQe-2502 User Manual

Page 65

Advertising
background image

Operation Theory

55

High-Hysteresis Analog Trigger Condition

Figure 4-29 shows the high-hysteresis analog trigger condition.
The trigger signal asserts when the input analog signal level is
higher than the High_Threshold voltage, where the hysteresis
region is determined by the Low_Threshold voltage.

Figure 4-29: High-Hysteresis Analog Trigger Condition

Low-Hysteresis Analog trigger condition

Figure 4-30 shows the low-hysteresis analog trigger condition.
The trigger signal asserts when the input analog signal level is
lower than the Low_Threshold voltage where the hysteresis
region is determined by the High_Threshold voltage.

Figure 4-30: Low-Hysteresis Analog Trigger Condition

Advertising