Ipmi commands, Able, Ipmi – ADLINK aTCA-N700 User Manual
Page 40: Command list
aTCA-N700 SW Users Guide
34
6.4. IPMI commands
The Intelligent Platform Management Interface (IPMI) is provided as a tool to monitor
and management the blade. The commands are in available in the bootloader
environment, which are summarized in Table 6-3.
Table 6-3 IPMI command list
Parameter
Description
reset
reset board by IPMC cmd
sol-mac <MAC_ADDR>
set mac address for sol
sol-mac
get mac address for sol
get-last-rst
get last reset reason
bmc <time> <act>
enable BMC watchdog with timer
active-flash
display active-flash number
switch-active
change active-flash
get-addr-info
get address info
get-msg-add-info
get msg address info
get-msg-shelf-addr
get msg shelf addr
get-device-id
get device information
auto-boot-switch
get auto boot status
auto-boot-switch (0|1)
set auto boot status(0 or 1)
The following is an example for an IPMI command which performs a BMC watchdog
reset.
=> ipmi get-addr-info
PICMGid: 0x00
HWAddr: 0x47
IPMB_0Addr: 0x8e
Reserved: 0xff
FRU_dev_info: 0x00
Site No: 0x00
Sitetype: 0x00
=> ipmi get-msg-add-info
chNo: 0x00
netFn: 0xb6
chksum_0: 0x4a
rsSA: 0x20
rqSeq: 0x00
cmdCode: 0x01
compCode: 0x00
PICMGid: 0x00
hwAddr: 0x47
rqSA: 0x8e
fixedData_0: 0xff
FRUid: 0x00
siteNo: 0x04
siteType: 0x00
chksum_1: 0x07
=> ipmi get-msg-shelf-addr
chNo: 0x00
netFn: 0xb6
chksum_0: 0x4a
rsSA: 0x20
rqSeq: 0x00
cmdCode: 0x02
compCode: 0x00
PICMGid: 0x00
ShelfAddr type: 0x03
ShelfAddrLen: 0x14
ShelfAddr[0]: 0x30