Ipmi commands, Able, Ipmi – ADLINK aTCA-N700 User Manual

Page 40: Command list

Advertising
background image

aTCA-N700 SW Users Guide

34

6.4. IPMI commands



The Intelligent Platform Management Interface (IPMI) is provided as a tool to monitor
and management the blade. The commands are in available in the bootloader
environment, which are summarized in Table 6-3.

Table 6-3 IPMI command list

Parameter

Description

reset

reset board by IPMC cmd

sol-mac <MAC_ADDR>

set mac address for sol

sol-mac

get mac address for sol

get-last-rst

get last reset reason

bmc <time> <act>

enable BMC watchdog with timer

active-flash

display active-flash number

switch-active

change active-flash

get-addr-info

get address info

get-msg-add-info

get msg address info

get-msg-shelf-addr

get msg shelf addr

get-device-id

get device information

auto-boot-switch

get auto boot status

auto-boot-switch (0|1)

set auto boot status(0 or 1)


The following is an example for an IPMI command which performs a BMC watchdog
reset.


=> ipmi get-addr-info
PICMGid: 0x00
HWAddr: 0x47
IPMB_0Addr: 0x8e
Reserved: 0xff
FRU_dev_info: 0x00
Site No: 0x00
Sitetype: 0x00

=> ipmi get-msg-add-info
chNo: 0x00
netFn: 0xb6
chksum_0: 0x4a
rsSA: 0x20
rqSeq: 0x00
cmdCode: 0x01
compCode: 0x00
PICMGid: 0x00
hwAddr: 0x47
rqSA: 0x8e
fixedData_0: 0xff
FRUid: 0x00
siteNo: 0x04
siteType: 0x00
chksum_1: 0x07
=> ipmi get-msg-shelf-addr
chNo: 0x00
netFn: 0xb6
chksum_0: 0x4a
rsSA: 0x20
rqSeq: 0x00
cmdCode: 0x02
compCode: 0x00
PICMGid: 0x00
ShelfAddr type: 0x03
ShelfAddrLen: 0x14
ShelfAddr[0]: 0x30

Advertising