3 printer initialization – AMT Datasouth M5TT Plus User Manual

Page 31

Advertising
background image

Document #120522 Rev-A

28

4.3 Printer Initialization

Printer initialization is used to clear DRAM and restore printer settings to defaults.
The only one exception is ribbon sensitivity, which will note be restored to default.

Printer initialization is activated by the following procedures.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns

green

after 5 amber blinks.

(Any green will

do during the 5 blinks).

The LED color will be changed in the following:

Amber red (5 blinks) amber (5 blinks)

green (5 blinks)

green/amber (5 blinks) red/amber (5 blinks) solid green

Printer configuration will be restore to defaults as below after initialization.

Parameter Default

setting

Speed

203DPI :127 mm/sec (5 ips)
300DPI: 76 mm/sec (3 ips)

Density 8
Label Width

4” (101.6 mm)

Label Height

4” (101.6 mm)

Sensor Type

Gap sensor

Gap Setting

0.12” (3.0 mm)

Print Direction

0

Reference Point

0,0 (upper left corner)

Offset 0
Tear Mode

On

Peel off Mode

Off

Cutter Mode

Off

Serial Port Settings 9600 bps, none parity, 8 data bits, 1 stop bit
Code Page

850

Country Code

001

Clear Flash Memory No
IP Address

DHCP

Note: Always do gap/black mark sensor calibration

after printer

initialization.

Advertising