4 black mark sensor setting and calibration, 5 gap sensor setting and calibration, 6 skip pal application program – AMT Datasouth M5TT Plus User Manual

Page 32

Advertising
background image

Document #120522 Rev-A

29

4.4 Black Mark Sensor Setting and Calibration


Please follow the steps as below.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns

green

/

amber

after 5 green blinks.

(Any

green/amber will do during the 5 blinks).

The LED color will be changed as following:
Amber red (5 blinks) amber (5 blinks) green (5 blinks)

green

/

amber

(5 blinks)

red/amber (5 blinks) solid green

4.5 Gap Sensor Setting and Calibration

Please follow the steps as below.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns

red

/

amber

after 5 green/amber blinks.

(Any

red/amber will do during the 5 blinks).

The LED color will be changed in the following:
Amber red (5 blinks) amber (5 blinks) green (5 blinks)
green/amber (5 blinks)

red

/

amber

(5 blinks)

solid green

4.6 Skip PAL application program

PAL programming language allows user to download an auto execution file to flash
memory. The printer will run the PAL application program immediately when
turning on printer power. The PAL application program can be interrupted by the
power-on utility.

Please follow the procedures below to skip a PAL application program:
1. Turn off printer power.

2. Press the FEED button and then turn on power.

Advertising