AMT Datasouth M5TT Plus User Manual

Page 38

Advertising
background image

Document #120522 Rev-A

35

Ribbon Sensor and

Gap/Black Mark

Sensor Calibration

1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3 Release the button when LED becomes

red

and blinking.

(Any red will do during the 5 blinks).

It will calibrate the ribbon sensor and gap/black mark
sensor sensitivity.

The LED color will be changed as following order
Amber

red

(5 blinks)

amber (5 blinks)

green

(5 blinks) green/amber (5 blinks) red/amber (5
blinks) solid green

Note:

Please select gap or black mark sensor by GAP or BLINE

command prior to calibrate the sensor.

For more information about GAP and BLINE command,

please refer to programming manual.

Gap/Black Mark

Sensor Calibratio,

Label Length

Measurement,

Self Test and enter

Dump Mode

1.Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED becomes

amber

and

blinking. (Any amber will do during the 5 blinks).

The LED color will be changed as following order.
Amber red (5 blinks)

amber

(5 blinks)

green

(5 blinks) green/amber (5 blinks) red/amber (5
blinks) solid green

It calibrates the sensor and measures the label
length and prints internal settings then enter the
dump mode.

Note:

Please select gap or black mark sensor by GAP or BLINE

command prior to calibrate the sensor.

For more information about GAP and BLINE command,

please refer to programming manual.

Advertising