Dolby

®

DP570 Multichannel Audio Tool User’s Manual

A Guide to Dolby Metadata

Parameter Definitions

Audio Production Information

This parameter indicates whether the mixing level and room type values are valid. 

Yes

 

indicates that a receiver or amplifier can use these values. 

No

indicates that these values are 

invalid. In practice, only high‐end consumer equipment implements these features.

Mixing Level

The Mixing Level parameter describes the peak SPL during the final mixing session at the 
studio or on the dubbing stage. The parameter allows a consumer’s amplifier to set its 
volume control to match that of the mixing room. This control operates in addition to the 
dialogue level control, and is best thought of as the final volume setting on the consumer’s 
equipment. This value can be determined by measuring the SPL of pink noise at studio 
reference level and then adding the amount of digital headroom above that level. For 
example, if 85 dB equates to a reference level of –20 dBFS; the mixing level is 85 + 20, or 105 
dB.

Room Type

The Room Type parameter describes the equalization used during the final mixing session 
at the studio or on the dubbing stage. A large room is a dubbing stage with the industry 
standard X‐curve equalization; a small room has flat equalization. This parameter allows 
an amplifier to be set to the same equalization as that heard in the final mixing 
environment.

Table D-11 Audio Production Information Settings and Definitions

Audio Production

Information Setting

Definition

Yes

Mixing Level and Room Type parameters are valid.

No

Mixing Level and Room Type parameters are invalid 
and should be ignored.

Table D-12 Mixing Level Setting

Mixing Level Setting

80 to 111 dB in 1 dB increments

Table D-13 Room Type Setting

Room Type Setting

Not Indicated

Large

Small