Most Important Metadata

3. Dialogue level: the dialnorm parameter. Compare the measured value (shown in 

yellow numbers) to the dialnorm metadata parameter value (shown in green 
numbers) periodically as you work.

4. Compression mode: select one that sounds best; None is not recommended as it may 

cause peak limiting in a consumerʹs decoder during downmixing. For more 
information on compression modes, see 

Setting Dynamic Range Control 

on page 34. 

Set it once for each program.

5. Surround –3dB Flag: Set this according to the setting of the original mixing room.  

Typically this flag is enabled when a mix was balanced on a theatrical dubbing or 
mixing stage where the surround channels were SPL‐adjusted to 82 and the main 
speakers were SPL‐adjusted to 85.

6. Downmix parameters: set according to taste:

Center downmix level

Surround downmix level

Preferred stereo downmix

Lt/Rt center downmix level

Lt/Rt surround downmix level

Lo/Ro center downmix level

Lo/Ro/ surround mix level