Monitoring dialogue level, 2 monitoring dialogue level, Figure 8-2 – Dolby Laboratories DP570 User Manual

Page 71: Figure 8-3

Advertising
background image

Using the DP570 in Master Control

Typical Activities

Dolby

®

DP570 Multichannel Audio Tool User’s Manual

59

Figure 8-2

Typical Downmix Options

Or, if a viewer complains about the audio quality on a mono television when viewing a 5.1 
program, the MC operator can quickly select Mono in the Downmix section, and RF to 
emulate the viewerʹs listening conditions.

8.2.2 Monitoring Dialogue Level

When changing programs or channels, refer to the dialogue level indicators to verify that 
the Dialogue Level value set in the software—the green numbers in Figure 8‐3—and the 
measured value—the yellow numbers in Figure 8‐3—of speech match ± 2 dB.

Figure 8-3

Dialogue Level Controls

If the Dialogue Level value doesn’t match, we recommend adjusting the overall audio level 
until it does.

In most cases short‐term measurements are best as they provide a measurement over a ten‐ 
second period of program audio and do not average the measurement over a long period 
of time. For more information on the measurement modes, see 

Measuring the Average 

Loudness of Identified Clips 

on page 31.

Note: A single program must have a single dialnorm value, and this value should not 

change within the program. Adjust audio levels to match dialnorm if necessary, 
rather than the other way around.

Advertising