Troubleshooting metadata problems, Outputting metadata, 4 troubleshooting metadata problems – Dolby Laboratories DP570 User Manual

Page 41: 5 outputting metadata, Figure 4-2

Advertising
background image

Using the DP570 Features

Troubleshooting Metadata Problems

Dolby

®

DP570 Multichannel Audio Tool User’s Manual

29

Figure 4-2

Adding a Second Program

4.4

Troubleshooting Metadata Problems

The DP570 has several status indicators to help troubleshoot metadata‐related problems.

The front‐panel status display shows the metadata source as External if any metadata 
source is set to external. 

Metadata Input

 indicators on both the DP570 front panel and in the DolbyRemote 570 

software provide status information. The indicators are green any time a valid metadata 
signal is present, whether or not it is being used. They turn red only when an external port 
is in use and there is a problem with the metadata signal.

The Metadata Params submenu under either the Setup or status menu on the 
front‐panel display can also be used to determine the current source for a parameter and 
its current value.

4.5

Outputting Metadata

You can choose to send metadata from the DP570 to downstream devices using the 

Metadata Output

 connector on the rear panel. The frame rate for output metadata is set by 

the received video reference signal and is locked to the beginning of the video frame.

Note: If the DP570 is using external metadata and there is a temporary error in the 

metadata stream, the unit continues to use the last valid metadata values. When 
the error clears, the DP570 resumes using the stream from the external port.

DP572

DP570

DP571

Digital

Output

Router
Output

Metadata Out

Digital
Input

Metadata
In

Metadata
In

Metadata

Out

Digital
Input

Metadata Adjustment

• Change Program Config

to 5.1+2 (internal source)

• Set parameters for new

two-channel program

D 563

P

In

Out

6

5.1

5.1+2

8

2