Approved coolant, Tier 4 engine, Rt45 operator’s manual – Ditch Witch RT45 User Manual

Page 139

Advertising
background image

Service - 142

RT45 Operator’s Manual

Tier 4 Engine

CMW

®

Approved Coolant

This unit was filled with John Deere Cool-Gard II coolant before shipment from factory. Add only John
Deere Cool-Gard II (p/n 255-006) or any fully formulated, ethylene glycol based, low-silicate, heavy-duty
diesel engine coolant meeting ASTM specification D6210.

Tier 4 Engine

The Deutz Tier 4 D2.9 L4 engine uses a computer-controlled fuel management system and diesel
oxidation catalytic converter (DOC).

Diagnostic and maintenance work may only be carried out by authorized personnel using equipment
approved by Deutz.

Deutz control units are equipped with self-diagnostics. Active and passive error codes are saved in the
error memory. Active errors are displayed on the electronic display panel or error lamp (flash code) CAN

bus. If error codes are recorded, contact your Ditch Witch

®

dealer.

Diesel engines that are equipped with an exhaust after treatment system (EAT) may only be operated with
an ultra low sulfur diesel fuel. See “Approved Fuel” on page 141.

NOTICE:

Use only pre-diluted coolant or concentrated coolant mixed with distilled water. Do not use tap
water.

Do not use water or high-silicate automotive-type coolant. This will lead to engine damage or
premature engine failure.

Do not mix heavy-duty diesel engine coolant and automotive-type coolant. This will lead to coolant
breakdown and engine damage.

Advertising