HITEC X1 Pro DC/DC Multi-Charger User Manual

Page 21

Advertising
background image

21

lITHIuM - balance cHarGe Mode (cont.)

before You beGIn cHarGInG Your baTTerY,

Make sure You HaVe read and undersTand

all of THe WarnInGs and safeTY InforMaTIon

conTaIned on PaGes 4-9.

Warning

See page 16 for the appropriate charging connections setup for

this operation.

First, select the correct battery type by fol-

lowing the instructions on page 18. Once you

have set the correct battery type, toggle up

(▲) or down (▼) until

you see the “

LiPo BALANCE

” screen.

Toggle right

(►) once and the amp rate val-

ue will begin flashing. Toggle up

(▲) or down

(▼) to adjust the value to the desired rate. Follow the instructions

provided with your battery when setting the amp rate.

Toggle right

(►) again and the cell count

value will begin flashing. Toggle up

(▲) or

down (

▼) to adjust the cell count. This will automatically change

the voltage value to the correct setting for the selected cell count.

The cell count should match the battery label exactly.

Toggle and hold the joysick to the right

(►) for three seconds and

you will see “

BATTERY ChECK WAIT...

” followed by the “

CON-

fIRM

/

CANCEL

“ screen.

This screen displays the number of cells

you set up as ”

R

” and the number of cells

detected by the processor as “

S

”. If both numbers are identical, you

may toggle right

(►) once to confirm and begin charging. If the

cell count does not match, toggle left

(◄) once to return to the

previous screen and carefully check the number of cells of the bat-

tery pack before proceeding.

LiPo BALANCE

0.8A

22.2V(6S)

LiPo BALANCE
0.8A

11.1V(3S)

R:3SER

S:3SER

CONfIRM(ENTER)

LiPo BALANCE

0.8A 22.2V(6S)

Advertising