HITEC X1 Pro DC/DC Multi-Charger User Manual

Page 40

Advertising
background image

40

discharge current setting
Toggle up

(▲) once to enter the “

DSCh

CURRENT

” screen. Toggle right

(►) once and the amperage value

will begin flashing. Toggle up

(▲) or down (▼) to change the

amperage value. Toggle right

(►) once to set the amperage.

discharge Voltage setting

(3.0-3.3v per cell)

Toggle up

(▲) once to enter the “

DSCh

VOLTAGE

” screen. Toggle right

(►) once and the voltage value will

begin flashing. Toggle up

(▲) or down (▼) to change the voltage

value. Toggle right

(►) once to set the voltage. Refer to page 7 for

recommended discharge voltages.

Terminal Voltage setting

(use at Your own risk)

Toggle up

(▲) once to enter the “

TVC=YOUR RISK!

” screen.

Toggle right

(►) once and the voltage value will begin flashing.

Toggle up

(▲) or down (▼) to change the voltage value. Toggle

right

(►) once to set the voltage.

Temperature cut-off
(when using optional temp sensor)
Toggle up

(▲) once to enter the “

TEM-

PERATURE CUT-Off

” screen. Toggle right

(►) once and the temperature value will

begin flashing. Toggle up

(▲) or down (▼)

to change the temperature value. Toggle

right

(►) once to set the temperature. The temperature can be set

between 20ºC and 80ºC.

Toggle up

(▲) once to enter the “

SAVE PROGRAM

” screen. Toggle

right

(►) once to save all of the settings previously entered.

baTTerY MeMorY (cont.)

DSCh CURRENT

2.2A

DSCh VOLTAGE

3.0V/CELL

TVC=YOUR RISK!

4.20V

TEMPERATURE
CUT-Off 50C

SAVE PROGRAM

ENTER

[ BATT MEMORY 1]
LiPo 7.4V(2S)

baTTerY MeMorY (cont.)

lITHIuM baTTerY MeTer

Advertising