HITEC X1 Pro DC/DC Multi-Charger User Manual

Page 14

Advertising
background image

14

feaTures (cont.)

PoWer suPPlY connecTIons

delta-Peak sensitivity for niMH/nicd

This automatic charge termination program is based on the prin-

ciple of delta-peak voltage detection. When the battery’s voltage

exceeds the threshold, the charging process will be terminated

automatically.

automatic charging current limit

The charging current can be set by the user when charging NiCd

or NiMH batteries. The "AUTO" charging mode, however, is recom-

mended when charging NiMH batteries with low impedance and

capacity.

capacity limit

The charging capacity is always calculated as the charging current

multiplied by time. The charging process will terminate automati-

cally if the charging capacity exceeds the limit set by the user.

Temperature Threshold

The battery’s internal chemical reaction will cause the tempera-

ture of the battery to rise. The charging process will terminate

automatically if the charger’s temperature exceeds the limit set by

the user.

Processing Time limit

Protect your battery by setting a maximum time limit for charging

and discharging.

Pc control software “charge Master”

The free “Hitec Charge Master” software gives you unparalleled

ability to operate the charger through your PC. You can monitor

pack voltage, cell voltage and other data during charging and

view charge data in real-time graphs. You can also initiate pro-

cesses, control charging and update fi rmware .

Advertising