LINK Systems OmniLink 5000 User Manual

Page 12

Advertising
background image

April 17, 2000

Man ual Revisio n 1.0

2.4

tonnage monitor limit.

The example above can be taken one additional step, if two press operators are given different user
names and different passwords. One operator can be assigned the ability to change tonnage monitor
limits in addition to the ability to reset tonnage monitor faults, while the other operator is not assigned
the ability to change the tonnage monitor limits.

Section 2.2.3 Password Only Mode

The “Password Only” mode allows for sixteen users. Each user can be assigned access to some or all of
the restricted items. This mode does not use the RUN/PROG key.

The example listed above indicated that setup personnel required access to all restricted items. In the
“Key or Password” mode, the setup personnel used the RUN/PROG key to gain access to all of the
restricted items. In the “Password Only” mode, the setup personnel can still have access to all of the
restricted items, but the system must be configured as such. The setup personnel must be assigned a user
name and password. In addition, all restricted items would be assigned access to the setup personnel.

Section 2.2.4 Key and Password Mode

The “Key and Password” mode requires the user to have the RUN/PROG key, user name, and user
password. Operation is basically the same as the Password only mode, except that in addition to
entering the password the user must switch the RUN/PROG key to the PROG position.

Section 2.2.5 Tonnage Monitor Restricted Items

The following table lists the tonnage monitor restricted items name and function.

TONNAGE MONITOR RESTRICTED ITEMS

NAME

FUNCTION

TM Bypass

Bypass the Tonnage Monitor

TM Reset

Reset Tonnage Monitor Faults

TM Peak High Limits

Change the Tonnage Monitor Peak High Limits

TM Peak Low Limits

Change the Tonnage Monitor Peak Low Limits

TM Reverse Limits

Change the Tonnage Monitor Reverse Limits

TM Auto Setup

Perform a Tonnage Monitor Automatic Setup

TM Data Windows

Change the Tonnage Monitor Data Windows High Limits, Low
Limits, Start Angle, and Stop Angle

Section 2.2.6 Access Control Operation

Advertising