Figure 7.5:

Strain Gage Mounting on Solid Frame Straight Side Machines

On solid frame straight side machines, the preferred strain gauge mounting location is inside the
"windows" under the ends of the crankshaft. A strain gauge should be mounted on the inside face of
each column forming the "windows" as shown in Figure 7.5.