April 17, 2000

Man ual Revisio n 1.0

4.4

Figure 4.3:

Example Data Window Tonnage View

Figure 4.3 shows a four channel screen when viewing data window tonnages. Notice that the major
difference between this screen and that of Figure 4.2 is the addition of three new parameters and the lack
of a REVERSE TONNAGE softkey.

Referring to Figure 4.3, some additional settings in a data window view are:

k) Data Window On/Off Setting

-

This determines whether the data window is active. When
“On”, the data window setpoints are enforced from the “On
Angle” to the “Off Angle”. When “Off”, these settings are
not used at all and will NOT stop the press.

l) Data Window On Angle

-

This is the angle at which the data window setpoints will
start to be enforced.

m) Data Window Off Angle

-

This is the angle at which data window setpoints stop being
enforced.