3.3 The Tonnage Monitor Diagnostic Screen

Pressing the DIAGNOS softkey in the main tonnage monitor screen will bring up the diagnostic screen
shown in Figure 8.

Stroke

Mode

Single Stroke

Drive

Speed

Stroke

Speed

SPM

SPM

0
0

Order

Counter

Current Status

Counter OFF

EXIT

0

0

Program/Run Switch

TOP

Tonnage
Monitor

VRef Voltage:
VRef Current:

10.01 Volts

mA

Tonnage Monitor Diagnostics

108

Tonnage Alarm Counters

Forward Machine Rating Alarms:

Reverse Machine Rating Alarms:

Total Torque Limit Alarms:

High Limit Alarms:

Low Limit Alarms:

Reverse Limit Alarms:

0
0
0
1
2
0

Stroke

Mode

Single Stroke

Drive

Speed

Stroke

Speed

SPM

SPM

0
0

Order

Counter

Current Status

Counter OFF

EXIT

0

0

Program/Run Switch

TOP

Tonnage
Monitor

VRef Voltage:
VRef Current:

10.01 Volts

mA

Tonnage Monitor Diagnostics

108

Tonnage Alarm Counters

Forward Machine Rating Alarms:

Reverse Machine Rating Alarms:

Total Torque Limit Alarms:

High Limit Alarms:

Low Limit Alarms:

Reverse Limit Alarms:

0
0
0
1
2
0

Figure 8: Tonnage Monitor Diagnostic Screen


Note that the alarms counters on this screen can only be reset from the Tonnage Monitor Machine
Settings Screen in the Tonnage Monitor Configuration area (see section 4.4.16 on page 47 for details).
Items on this screen include:

VRef Voltage

The tonnage monitor reads back its’ own reference voltage and reports it here.
The voltage should be between 9.90 and 10.10 volts. This value is useful for
troubleshooting “Reference Shorted” errors. If the voltage is near 0, then a
short to ground is likely.

VRef Current

This is the current in milliamps being drawn from the reference supply to drive
the strain gages. For the 350 ohm gages that Link typically uses, the draw
should be approximately 28 milliamps per gage connected.

Forward Machine
Rating Alarms

The number of forward machine rating alarms that have occurred since the last
time the alarm counters were reset.