2 intermediate weld pad mounting, Intermediate weld pad mounting – LINK Systems 5100-8 Tonnage & Analog Signal Monitor User Manual

Page 59

Advertising
background image



Doc

#:

L-802-1110 Page

57 Rev.

02

Crankshaft

End

Strain Links

Crankshaft

End

Strain Links

On solid frame straight side machines,
the preferred strain gage mounting
location is inside the "windows" under
the ends of the crankshaft. A strain
gage should be mounted on the inside
face of each column forming the
"windows" as shown in Figure 31.

















Figure 31: Solid Frame Machine Gage Locations

6.7 Strain Gage Mounting

Strain gages may be bolted directly to the machine or bolted to intermediate pads welded or adhered to
the machine.

6.7.1 Direct Machine Mounting

1) Select the desired mounting locations for the strain gages.

2) Remove paint, oil, grease, etc., to obtain a bare metal surface slightly larger than the LST-1000

strain gage. The metal surface must be flat and smooth so that the strain gage is not warped and
contacts the surface area evenly when mounted. A mounting surface that is flat to within .0025
inches and with a 250 micro-inch or less finish will give best results. Grind the surface if
necessary.

3) Scribe a line on the metal surface on which the strain gage is to be mounted in the direction of

tension or compression of the structural member. This will be a vertical line on columns or tie
rods of straight side presses and "C" frame machines that are not inclined. On inclined presses,
the scribe marks should follow the inclined angle.