2 specifications – LINK Systems 5100-8 Tonnage & Analog Signal Monitor User Manual

Page 8

Advertising
background image



Doc

#:

L-802-1110 Page

6

Rev.

02

• Inside the monitoring region additional sets of high and low Limits (data windows) can be set to

become active at specific crankshaft angles. Up to four data windows can be programmed for each
job and can be used to monitor the tonnage of specific die features – for example, an individual
punch.


• A maximum allowable forward tonnage limit for the machine is established when the module is

installed, based on the capacity of the machine (Machine Rating) and cannot be turned off.


• If desired, additional limits can be placed on the total tonnage that reflects the maximum allowable

total tonnage at specific positions in the stroke.


• Limits can be programmed manually, automatically calculated by the Tonnage and Analog Signal

Monitor module, or recalled along with all other Link equipment settings through the use of job
setups.


• Status messages for each channel indicate the first alarm condition that occurred during the stroke.

• Low limits can be set to automatically bypass when in a setup mode, if desired. These limits are

then automatically restored when switching back to a production mode. This feature typically
eliminates the need to manually bypass all limits on the tonnage monitor and the associated risk of
forgetting to un-bypass it.


• If manually bypassing all limits on the tonnage monitor is needed, a setting is available that will

automatically un-bypass the tonnage monitor when switching back to a production mode.


• For each job, low limits can be set to automatically bypass when a bad or empty part is in the part

tracking registers.


• For each job, low limits can be set to automatically bypass for the first few strokes (user selected

number) to accommodate presses that “ramp up” to speed causing false low limit alarms on startup.
This setting also works in conjunction with the auto-setup feature to allow accurate setpoints in these
cases.

1.2 Specifications

Size:

2.25” wide, 10.50” high, 7” deep


Input Power:

88-264VAC, 47-63Hz, 50 Watt


Fuse:

5mm X 20mm, 2 Amp, 250 Volt, Fast Blow


Output Power:

24VDC, 0.8 Amps max (for optional Die Protection sensors)


Gain Range:

189 to 14164


Press Speed Capability:

Up to 2000 strokes per minute

Advertising