PowerPlay Early Power Estimator Input Values

Figure 3–19. High-Speed Transceiver Block Section in the Stratix GX PowerPlay Early Power Estimator

Power-Up I

CC

Power-up I

CC

is and estimation of the current required to successfully

power-up the device and is observed on the V

CCINT

power supply. For

Stratix and Stratix GX devices, the PowerPlay early power estimator
provides both the typical and maximum power-up I

CC

. For Cyclone

devices, the PowerPlay early power estimator provides the maximum
power-up I

CC

.

The power-up I

CC

current is not added to the total current (I

CCINT

) because

it is only observed when the device is powering up. The power-up
current is independent of the current consumption during device
user-mode. If the power-up I

CC

is greater than the total I

CCINT

, you should

select a regulator that supports the maximum power-up I

CC

requirement.

f

For more information on power-up I

CC

, refer to the DC & Switching

Characteristics chapter of the appropriate device family handbook.

Total

The Total section displays the total current and power estimation for the
internal logic array (Internal V

CCINT

), the I/O interface (I/O (V

CCIO

)), the

transceiver (Transceiver (V

CC

)), if applicable, and the total power

consumption for the whole design. The total I

CCINT

and P

INT

are the

summation of all the subtotals of the I

CCINT

and P

INT

calculated in each

section. The total I

CCIO

and P

IO

are the summation of all the subtotals of

the I

CCIO

and P

IO

calculated in the relevant sections. For the Stratix GX

PowerPlay early power estimator, the total power consumed by the
high-speed transceiver blocks is listed separately as P

TRANSCEIVER

. The

Advertising