Using PowerPlay Early Power Estimator for Stratix, Stratix GX & Cyclone FPGAs

total P

INT

, total P

IO

, P

TRANSCEIVER

(for Stratix GX devices only), and total

PowerPlay early power estimator are also displayed in the Device section
at the top of the PowerPlay early power estimator.

Thermal Analysis

In the Thermal Analysis section, enter the device’s ambient temperature
(T

a

) in degrees Celsius. T

j

is the maximum recommended operating

junction temperature based on the temperature grade of the device you
choose. The required junction-to-ambient thermal resistance (

θ

JA

) is the

minimum

θ

JA

for the ambient temperature you entered and the amount

of power your design consumes. The required

θ

JA

must be greater than

the

θ

JA

for the chosen device and package.

Based on the device and package you selected in the Device section, the
PowerPlay early power estimator determines the junction-to-case
thermal resistance (

θ

JC

) and

θ

JA

at still air and air flow rates of 100, 200,

and 400 LFpM. These numbers are obtained from the Altera Device
Package Information Data Sheet
.

The maximum allowable power (P

MAX

) is calculated based on the device

package chosen and the ambient temperature using the following
equation:

(T

j

- T

a

) /

θ

JA

= P

MAX

The P

MAX

is reported for still air and air flow rates of 100, 200, and

400 LFpM. If the calculated power of your design is greater than the P

MAX

for the chosen device and package, you need to take the appropriate
thermal measures by adding a heat sink or cooling fan on your board.

If you are not using a heat sink, refer to the Without Heat Sink section of
the PowerPlay early power estimator, which displays whether your
selected device package

θ

JA

is less than the required

θ

JA

of your design at

still air or with airflow. “Good” indicates that the package

θ

JA

is less than

the minimum required

θ

JA

for your design. A blank result indicates that

the package

θ

JA

is more than the minimum required

θ

JA

. “No Value”

indicates that you have not completely entered the required information.

If you need to use a heat sink, you need to enter the case-to-heat sink
thermal resistance (

θ

CS

) and heat sink-to-ambient thermal resistance (

θ

SA

)

at still air and airflow rates of 100, 200, and 400 LFpM. The heat sink
manufacturer should specify these values. The results in the With Heat
Sink

section tells you whether your device package

θ

JA

is less than the

required

θ

JA

at still air or with airflow when using a heat sink. A blank