4–4

Chapter 4: Development Board Setup

Factory Default Switch Jumper Settings

Transceiver Signal Integrity Development Kit,

February 2013

Altera Corporation

Stratix V GT Edition User Guide

4. Set DIP switch bank (SW4) to match

Table 4–4

and

Figure 4–1

.

5. Set DIP switch bank (SW5) to match

Table 4–5

and

Figure 4–1

.

3

SW7-3 VCCT_GTB

Switch 3 has the following sequence enable
options:

ON position = VCCT_GTB is enabled.

OFF position = VCCT_GTB is disabled.

ON

4

SW7-4 VCCL_GTB

Switch 4 has the following sequence enable
options:

ON position = VCCL_GTB is enabled.

OFF position = VCCL_GTB is disabled.

ON

Table 4–4. SW4 User DIP Switch Settings

Switch

Board

Label

Function

Default

Position

1

S5_UNLOCK

Switch 1 has the following options:

Closed (0) = FACTORY command won’t be issued.
JTAG will be locked out if FPGA is configured on
power-up from flash.

Open (1) = Unlock the FPGA and allow FACTORY
command. JTAG will be available even if FPGA is
configured on power-up from flash.

Open (1)

2–8

DPI6—DPI0

User defined options.

Table 4–5. SW5 DIP Switch Settings

Switch

Board

Label

Function

Default

Position

1

S0

Determines S5GT_CLK11 frequency.

(1)

Closed

2

S1

Determines S5GT_CLK11 frequency.

Open

3

SS0

Determines S5GT_CLK11 spectrum spread.

(1)

Open

4

SS1

Determines S5GT_CLK11 spectrum spread.

Open

Note to:

Table 4–5

(1) Truth tables for the SW5 settings:

S1S0Frequency
00-25 MHz
01-100 MHz (default)
10-125 MHz
11-200 MHz
SS1SS0Spread %
00-center =/- 25%
01-down -0.5%
10-down -0.75%
11-no spread (default)

Table 4–3. SW7 DIP Switch Settings

Switch

Board

Label

Function

Default

Position