LEd1
LEd2
LEd3
LEd4

Support of alarm signalling. In
the situation when the support
function is switched on , after
the alarm state retreat, the
signalling diode is not blanked
. It signals the alarm state till its
blanking moment by means of
the

push-but-

ton combination. This function
concerns only and exclusively
the alarm signaling, thus relay
contacts will operate without
support according to the chosen
type of alarm.

oFF – function switched off
on – function switched on

out

Parameter

symbol

Description

Range of changes

P_An

Input quantity, on which the
analog output has to react..

InP – main input (indicated

value).
HoUr – Real Time Clock

AnL

Lower threshold of the analog
output. One must give the value,
for which we want to obtain the
minimal value of signal on the
analog output.

-19999...99999

AnH

Upper threshold of the analog
output. One must give the value
on which we want to obtain the
maximal value of signal on the
analog output( 10 V or 20 mA).

-19999...99999

tYPA

Analog output type.

0_10U – napięciowe 0..10V
0_20A – prądowe 0..20mA
4_20A – prądowe 4..20mA