Anchor drive set-up (rs-12 single speed model), 4 pengo revtrak manual – Pengo RevTrak User Manual

Page 14

Advertising
background image

4

PENGO RevTrak Manual

TOLERANCES UNLESS OTHERWISE SPECIFIED

.X .1 [2.54 .XX .03 [.76] .XXX .010 [.25] ANGLE 1 DEG.

LBS

Kg

0.00

Figure 2C

THIS DRAWING IS THE PROPERTY OF PENGO 500 E.

HIGHWAY 10 LAURENS, IA. 50554. NO USE THEREOF SHALL

BE MADE OTHER THAN AS A REFERENCE FOR PROPOSALS

SUBMITTED BY PENGO CORPORATION AND/OR FOR JOBS

BEING EXECUTED IN CONFORMITY WITH SUCH PROPOSALS

HAVE BEEN ACCEPTED. UNLESS THE CONSENT OF SAID

PENGO CORPORATION HAS BEEN PREVIOUSLY OBTAINED.

NO PART OF THIS DRAWING SHALL BE COPPIED OR

DUPLICATED OR IT'S CONTENTS DISCLOSED.

DRAWN BY

MATERIAL

TITLE:

SIZE

REV

SCALE: 1:8

SHEET 1 OF 1

HEAT TREAT

THIRD ANGLE PROJECTION

B

DATE

CHECKED BY

NOTE: The following instruction steps are for PENGO RS series Drives only.

ANChOR DRIvE SET-UP (RS-12 SINGLE SPEED MODEL)

Remove bail housing to expose hydraulic motor.

Note: before removing the bail housing scribe a line from the housing to the gearbox to indicate a reference mark

for re-assembly.

1

Secure wire harness (4) to the transducers (6). Clip

harness end marked “

Pressure” to the pressure

side transducer and the harness end labeled

Tank” to the Tank side transducer. See figure 2C.

Note: The harness end labeled “Sequence” will not be

used on single speed units.

3

Fasten controller (3) to the bail housing as shown

in figure 3C with bolts (17) and nuts (18). The bail

housing will have existing holes typically located

on the front face of the housing.

4

Figure C

Figure 2C

Figure 3C

Remove the steel plug caps from the elbows

located on the hydraulic motor block. Once the

caps have been removed install two transducers

(6) as shown in figure 1C.

Note: use of Teflon tape on the threads of the transducers

is highly recommended to reduce potential leaks.

2

TOLERANCES UNLESS OTHERWISE SPECIFIED

.X .1 [2.54 .XX .03 [.76] .XXX .010 [.25] ANGLE 1 DEG.

LBS

Kg

0.00

Figure 1C

THIS DRAWING IS THE PROPERTY OF PENGO 500 E.

HIGHWAY 10 LAURENS, IA. 50554. NO USE THEREOF SHALL

BE MADE OTHER THAN AS A REFERENCE FOR PROPOSALS

SUBMITTED BY PENGO CORPORATION AND/OR FOR JOBS

BEING EXECUTED IN CONFORMITY WITH SUCH PROPOSALS

HAVE BEEN ACCEPTED. UNLESS THE CONSENT OF SAID

PENGO CORPORATION HAS BEEN PREVIOUSLY OBTAINED.

NO PART OF THIS DRAWING SHALL BE COPPIED OR

DUPLICATED OR IT'S CONTENTS DISCLOSED.

DRAWN BY

MATERIAL

TITLE:

SIZE

REV

SCALE: 1:1

SHEET 1 OF 1

HEAT TREAT

THIRD ANGLE PROJECTION

B

DATE

CHECKED BY

6

6

4

TOLERANCES UNLESS OTHERWISE SPECIFIED

.X .1 [2.54 .XX .03 [.76] .XXX .010 [.25] ANGLE 1 DEG.

LBS

Kg

0.00

Figure 3C

THIS DRAWING IS THE PROPERTY OF PENGO 500 E.

HIGHWAY 10 LAURENS, IA. 50554. NO USE THEREOF SHALL

BE MADE OTHER THAN AS A REFERENCE FOR PROPOSALS

SUBMITTED BY PENGO CORPORATION AND/OR FOR JOBS

BEING EXECUTED IN CONFORMITY WITH SUCH PROPOSALS

HAVE BEEN ACCEPTED. UNLESS THE CONSENT OF SAID

PENGO CORPORATION HAS BEEN PREVIOUSLY OBTAINED.

NO PART OF THIS DRAWING SHALL BE COPPIED OR

DUPLICATED OR IT'S CONTENTS DISCLOSED.

DRAWN BY

MATERIAL

TITLE:

SIZE

REV

SCALE: 1:1

SHEET 1 OF 1

HEAT TREAT

THIRD ANGLE PROJECTION

B

DATE

CHECKED BY

3

7

8

Pressure

Tank

Advertising